8 TON CHILLER GLYCOL AIR COOLED

$ 6464.3

Availability: 67 in stock
  • Item Width: 34
  • Power Phase: 3 Phase
  • Country/Region of Manufacture: United States
  • Item Height: 29
  • Temperature: 46 F
  • Modified Item: No
  • Brand: Brother Industrial Equipment
  • Cooling Capacity: 8 ton
  • Suitable For: Air Conditioning
  • Installation Area: exterior
  • Type: GLYCOL AIR-COOLED CHILLER
  • MPN: 11-1138-311
  • Condition: Chiller is new, uninstalled, built by Brother Industrial Equipment, year 2020. 1-year standard commercial warranty included.
  • Material: Stainless Steel
  • Components: Compressor
  • Compressor Type: Scroll
  • Refrigerant: R22 Compatible
  • Item Length: 53
  • BTU Cooling Rating: 96000 btu
  • Model: Modular Air-Cooled Glycol
  • Custom Bundle: No
  • All returns accepted: ReturnsNotAccepted
  • Supply Voltage: 460 V
  • Item Weight: 716
  • Features: Auto-Shut off Valve
  • Year Manufactured: 2020

    Description

    Chillers by Brother Industrial Equipment are NOT off-the-shelf and
    NOT FROM CHINA
    .  We don't buy cheap HVAC equipment (like an outdoor condensing unit) from your local refrigeration shop, pair it with a heat exchanger and call it our own.  We design and engineer from ground up, often times based on customer requirements.
    This is a 2020 model with all the buttons and bows, offered at a discounted price.
    MSRP is 324.00.
    -
    Designed to deliver 8-tons with 33% propylene glycol as a medium.
    Some manufacturers say that their chiller is glycol rated, that may be true, but does it deliver the rated tonnage with glycol as a medium?  Most chillers are tonnage rated with water, if glycol is used as a medium, the output of the chiller is decreased below that of the unit rating.
    - High ambient temperature operation
    ; up to 110 F and as lows as 30 F, AND delivers the nominal tonnage rating in those conditions.  Most manufactures say their equipment will operate in those conditions, but it is with a decreased output.
    - Includes Sensors
    for Refrigerant Pressure, Medium Temperature (IN/OUT), Medium Flow and Display (Supply).  Data is delivered via our ROI harness for display on your PLC controller.  Medium Flow Sensor features a local display, sensors do not have to be connected to PLC controller in order for chiller to operate, these are ancillary options installed.
    -
    High-End components
    include Baldor Motors, Copeland Compressors, Copper/Stainless brazed plat exchangers, Sporlan Valves, composite fan blades, stainless fasteners, plumbing and chassis.
    - Fault Switches
    installed include High Pressure, Low Pressure, Low Temperature, Medium Flow (integrated with sensor)
    - Features:
    - Our exclusive
    System Status Interface
    , a local interface for managing and observing important functions such as Medium
    Temperature Setpoint and System Fault Indications.
    - Our exclusive
    Remote Output Integration
    harness. This harness includes all data outputs from our SSI panel and allows
    for the integration into a central control and monitoring system. If well equipped, all sensor data outputs are also included in the ROI harness.
    - Exterior condenser filters, reduce cleaning intervals, increase longevity and improve performance
    - Coated aluminum condenser fins to increase longevity
    - Quick-Access panels offer convenient access to piping connections, refrigerant devices and control components.
    - Analog Control System that utilizes CE/UL approved components
    - Compressor heater, for easy start-up in low ambient temperatures, Self-Regulating
    - Discharge By-Pass system allows for chilled medium production during cold ambient temperatures
    Specifications:
    COOLING METHOD:                      AIR-COOLED
    NOMINAL MEDIUM FLOW RATE: 20 GPM
    MEDIUM:                                        PROPYLENE GLYCOL/WATER OR WATER
    MEDIUM RATIO:                            33% GLYCOL
    MEDIUM SETPOINT:                     46 F
    MEDIUM PRESSURE DROP:       10.15 PSI
    UNIT OUTPUT:                               96000 BTU
    SERVICE:                                       460/3/60
    CURRENT:                                      25.90 A**
    POWER:                                         15.90 kW**
    COMPRESSORS:                          1, SCROLL
    COMPRESSOR OIL:                      POE ***
    REFRIGERANT:                             R422B
    CONDENSERS:                             2
    CONDENSER MATERIAL:             AL FINS/CU TUBES
    HIGH AMBIENT:                             110 F
    LOW AMBIENT:                              30 F
    ALTITUDE LIMIT:                            2254 FT
    CABINET MATERIAL:                     316 SS
    *OPERATIONAL @ 50Hz, WITH APPROXIMATELY 17-18% REDUCED OUTPUT CAPACITY
    **CURRENT/POWER IS STATED FOR INSTALLED COMPONENTS ONLY AND ARE CALCULATED USING DESIGN PARAMETERS, SEE EQUIPMENT NAMEPLATES FOR SERVICE SIZING.
    ***USE OF CPVC/PVC/ABS MATERIAL FOR CHILLED WATER PLUMBING IS ADVISED AGAINST WHEN POE COMPRESSOR OIL IS USED.
    All Sales are as per Brother's Terms and Conditions and Brother's Warranty Statement, ask us for copies of these documents.
    Equipment is in stock, and will be tested and verified prior to shipping.  Shipping is approximately 1-week post payment.  LTL Ground Shipping to commercial addresses in lower 48 Contiguous United States or Canada.
    Destination liftgate not allowed.